Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Assoc Med Microbiol Infect Dis Can ; 7(3): 186-195, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-2054879

ABSTRACT

BACKGROUND: Serological assays designed to detect SARS-CoV-2 antibodies are being used in serological surveys and other specialized applications. As a result, and to ensure that the outcomes of serological testing meet high quality standards, evaluations are required to assess the performance of these assays and the proficiency of laboratories performing them. METHODS: A panel of 60 plasma/serum samples from blood donors who had reverse transcriptase-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 infections and 21 SARS-CoV-2 negative samples were secured and distributed to interested laboratories within Canada (n = 30) and the United States (n = 1). Participating laboratories were asked to provide details on the diagnostic assays used, the platforms the assays were performed on, and the results obtained for each panel sample. Laboratories were blinded with respect to the expected outcomes. RESULTS: The performance of the different assays evaluated was excellent, with the high-throughput platforms of Roche, Ortho, and Siemens demonstrating 100% sensitivity. Most other high-throughput platforms had sensitivities of >93%, with the exception of the IgG assay using the Abbott ARCHITECT which had an average sensitivity of only 87%. The majority of the high-throughput platforms also demonstrated very good specificities (>97%). CONCLUSION: This proficiency study demonstrates that most of the SARS-CoV-2 serological assays utilized by provincial public health or hospital laboratories in Canada have acceptable sensitivity and excellent specificity.


HISTORIQUE: Les dosages sérologiques conçus pour dépister les anticorps anti-SRAS-CoV-2 sont utilisés dans les études sérologiques et d'autres applications spécialisées. Par conséquent, et pour s'assurer que leurs résultats respectent des normes de qualité, il faut procéder à des évaluations de leur performance et de la compétence des laboratoires à les effectuer. MÉTHODOLOGIE: Les chercheurs ont obtenu une batterie de 60 prélèvements de plasma et de sérum chez des donneurs dont l'amplification en chaîne par polymérase après transcription inverse (RT-PCR) avait confirmé des infections par le SRAS-CoV-2 et de 21 prélèvements dont les résultats étaient négatifs au SRAS-CoV-2 et les ont distribués aux laboratoires intéressés du Canada (n = 30) et des États-Unis (n = 1). Ils ont invité les laboratoires participants à fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages étaient exécutés et les résultats obtenus pour chaque échantillon. Les chercheurs ont demandé aux laboratoires participants de fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages ont été effectués, et les résultats obtenus à l'égard de chaque échantillon. Les laboratoires ont mené les études à l'insu des résultats escomptés. RÉSULTATS: Les divers dosages avaient une excellente exécution, les plateformes à haut débit de Roche, d'Ortho et de Siemens démontrant une sensibilité de 100 %. La plupart des autres plateformes à haut débit avaient des sensibilités de plus de 93 %, à l'exception des dosages des IgG faisant appel à l'analyseur ARCHITECT d'Abbott, dont la sensibilité moyenne était de seulement 87 %. La majorité des plateformes à haut débit avaient également une très bonne spécificité (plus de 97 %). CONCLUSION: La présente étude de compétence démontre que la plupart des dosages sérologiques du SRAS-CoV-2 évalués dans des laboratoires sanitaires provinciaux ou les laboratoires hospitaliers du Canada possèdent une sensibilité acceptable et une excellente spécificité.

2.
Heliyon ; 8(9): e10270, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-2004106

ABSTRACT

The extent of the COVID-19 pandemic will be better understood through serosurveys and SARS-CoV-2 antibody testing. Dried blood spot (DBS) samples will play a central role in large scale serosurveillance by simplifying biological specimen collection and transportation, especially in Canada. Direct comparative performance data on multiplex SARS-CoV-2 assays resulting from identical DBS samples are currently lacking. In our study, we aimed to provide performance data for the BioPlex 2200 SARS-CoV-2 IgG (Bio-Rad), V-PLEX SARS-CoV-2 Panel 2 IgG (MSD), and Elecsys Anti-SARS-CoV-2 (Roche) commercial assays, as well as for two highly scalable in-house assays (University of Ottawa and Mount Sinai Hospital protocols) to assess their suitability for DBS-based SARS-CoV-2 DBS serosurveillance. These assays were evaluated against identical panels of DBS samples collected from convalescent COVID-19 patients (n = 97) and individuals undergoing routine sexually transmitted and bloodborne infection (STBBI) testing prior to the COVID-19 pandemic (n = 90). Our findings suggest that several assays are suitable for serosurveillance (sensitivity >97% and specificity >98%). In contrast to other reports, we did not observe an improvement in performance using multiple antigen consensus-based rules to establish overall seropositivity. This may be due to our DBS panel which consisted of samples collected from convalescent COVID-19 patients with significant anti-spike, -receptor binding domain (RBD), and -nucleocapsid antibody titers. This study demonstrates that biological specimens collected as DBS coupled with one of several readily available assays are useful for large-scale COVID-19 serosurveillance.

3.
PLoS Pathog ; 18(5): e1010471, 2022 05.
Article in English | MEDLINE | ID: covidwho-1833668

ABSTRACT

The ability to treat severe viral infections is limited by our understanding of the mechanisms behind virus-induced immunopathology. While the role of type I interferons (IFNs) in early control of viral replication is clear, less is known about how IFNs can regulate the development of immunopathology and affect disease outcomes. Here, we report that absence of type I IFN receptor (IFNAR) is associated with extensive immunopathology following mucosal viral infection. This pathology occurred independent of viral load or type II immunity but required the presence of macrophages and IL-6. The depletion of macrophages and inhibition of IL-6 signaling significantly abrogated immunopathology. Tissue destruction was mediated by macrophage-derived matrix metalloproteinases (MMPs), as MMP inhibition by doxycycline and Ro 28-2653 reduced the severity of tissue pathology. Analysis of post-mortem COVID-19 patient lungs also displayed significant upregulation of the expression of MMPs and accumulation of macrophages. Overall, we demonstrate that IFNs inhibit macrophage-mediated MMP production to prevent virus-induced immunopathology and uncover MMPs as a therapeutic target towards viral infections.


Subject(s)
COVID-19 , Interferon Type I , Orthomyxoviridae Infections , Humans , Interleukin-6/metabolism , Macrophages/metabolism , Proteolysis
4.
J Clin Virol ; 142: 104933, 2021 09.
Article in English | MEDLINE | ID: covidwho-1345391

ABSTRACT

BACKGROUND: COVID-19 seroprevalence studies use serum/plasma samples to detect SARS-CoV-2 IgG. Data supporting alternate specimen types and freeze-thaw antibody stability is lacking. The stability of IgG and other immunoglobulins in multiple blood sample types stored in differing conditions and multiple freeze-thaw cycles (FTCs) was evaluated. MATERIALS AND METHODS: Serum, plasma, and heparinized-plasma samples were collected from COVID-19 recovered individuals. Samples underwent testing for SARS-CoV-2 antibodies upon collection, after each of 10-12 FTCs, and storage at -70°C, -20°C, 4°C, and room-temperature for 10-12 days using four high-throughput commercial assays, two rapid-test cassettes, a manual ELISA, and a surrogate neutralization assay. RESULTS: All three specimen types were collected from 34 COVID-19 recovered seropositive individuals (≥21 days post-symptoms). Using the Architect and Liaison assays, a positive qualitative SARS-CoV-2 IgG result was detected daily up to 12 FTCs and up to 10 days of storage at different temperatures. An additional 25 plasma samples consistently demonstrated detection of SARS-CoV-2 antibodies daily after 12 FTCs and storage at -20°C using two rapid test cassette assays (SD Biosensor and Hangzhou All Test), manual (Beijing Wantai) and surrogate neutralization (GenScript) ELISAs, and two high-throughput assays (Roche Elecsys nucleocapsid and spike). IgM antibodies were less frequently detected by one of the rapid test cassette assays. CONCLUSIONS: Serum, plasma, and heparinized-plasma constitute reliable samples for SARS-CoV-2 antibody detection. In particular, the IgG response was stable and reliably detected after multiple FTCs and storage at common laboratory conditions. IgM detection was variable due to the labile nature of this antibody class.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Immunoglobulin G , Laboratories , Sensitivity and Specificity , Seroepidemiologic Studies
SELECTION OF CITATIONS
SEARCH DETAIL